Wind screens for data centers keep the warm air blown out by roof-mounted cooling systems away from the intake side of those systems. Wind can push that warm air back down, causing chillers and dry coolers to draw in heated air and achieve lower efficiency. A custom-designed wind screen made of high-quality technical textile breaks up that airflow and keeps the cooling stable.
A data center produces heat day and night, and that heat leaves the building via cooling systems such as chillers and dry coolers, which are often located on the roof of the data center. In calm conditions, the expelled air rises and disappears above the building. In windy conditions, this picture changes, because the airflow over the roof edge pushes the warm plume back down to the point where the chillers draw in their air.
A cooling system that has to operate with heated air consumes more energy and loses cooling capacity. On hot days, when the data center's cooling is already running close to its limit, the site manager is left with less margin as a result. In an environment where servers must run continuously, every degree on the intake side weighs in on energy consumption and the operational reliability of the entire data center.
Dexcon is installing wind screens made of high-quality technical textile on the roof of the data center, at the level of the chillers and other cooling systems. The wind screen breaks the wind that pushes back the warm air, allowing the expelled air to rise and the cooling systems to draw in cooler outside air.
The permeability of the wind screen is calculated per project. A completely closed wall catches the full force of the wind and directs it over the edge with turbulence, whereas a screen that is too open slows down the airflow too little. The correct openness lies somewhere in between and depends on the placement, the height of the wind screen, the configuration of the cooling systems, and the local wind conditions around the data center.
A windbreak on the roof of a data center is higher and more exposed than a screen on the site itself. Every windbreak for a data center is therefore custom-made, and for each project, Dexcon calculates the loads acting on the screen and the structure based on the location, building height, and roof shape. These calculations determine the dimensions of the structure and the method of anchoring the windbreak.
The wind load is the force exerted by the wind on the windbreak and on the supporting structure. Wind speed increases with height, and airflow accelerates around the roof edge of a building, causing a windbreak on a data center to be subjected to a heavier load than a screen at ground level. The wind load calculation takes into account the site location, building height, surroundings, and the openness of the textile.
The snow load is the weight of the snow that falls onto the structure. Wind can accumulate snow on a roof against upright parts, such as a windbreak or a cooling system, causing the load to be locally higher than on the rest of the roof. Dexcon takes this snow load into account when dimensioning the structure and the anchoring.
The rain load is the extra weight and pressure of rainwater on the fabric and the structure, especially during driving rain, when wind and rain act on the screen together. This load is also calculated per project and taken into account in the design of the windbreak.
Dexcon oversees the entire engineering process, from initial technical analysis and calculations to a detailed solution that is securely and permanently mounted on the data center roof. Where the situation permits, components are first assembled on the ground, which limits work at height and increases the safety of the assembly crew.
The high-quality technical textile is tensioned using aluminum tension profiles along the entire edge of the windscreen. The tension is distributed evenly across the entire surface, without point loading on individual attachment points. A fabric that is equally taut everywhere moves less in the wind, which limits wear on the textile and the fastenings.
That uniform tension distinguishes our data center wind screens from systems that use individual tension points. For a data center, where every intervention on the roof must be planned around a continuously running cooling system, that operational reliability is of paramount importance.
The screen consists of high-quality technical textile with UV protection and has fire class B-s2,d0 according to the European classification for the response in case of fire
Dexcon brings the same expertise in wind load and high-performance technical textiles that it applies to industrial sites, recycling sites, and logistics centers to the roofs of data centers. On those sites, Dexcon installs, among other things fixed screens and an overview of other completed installations can be found at the projects Every project begins with a free technical analysis of your site, after which Dexcon handles the design, calculations, and coordination of the installation.
Request your analysis or contact us to discuss your projects.
Wind can push the warm air that chillers and dry coolers blow out onto the roof back down. The cooling systems then draw in that heated air again, causing them to consume more energy and lose capacity. Wind screens made of high-quality technical textile break up that airflow and keep the intake air cooler.
We work with high-quality technical textiles with UV protection and fire class B-s2,d0 according to the European classification for the response to fire. Which class is required depends on the sector, the activity, and the building.
Dexcon oversees the entire engineering process. The project starts with a technical analysis, followed by the calculation of wind load, snow load, rain load, and other loads, after which the structure and anchoring on the roof can be worked out.